This category 7A S/FTP data cable is characterized by high performance reserves and outstanding quality, with excellent shielding performance thanks to individually shielded pairs and a tinned copper braid overall shield. Suitable for information transfer systems up to 1000MHz, 10Gbps Ethernet Signal transmission in audio, video and data applications. For structured cabling according to ANSI EIA / TIA 568, ISO / IEC 11801 and EN 50173 Class FA.





Available packages and colors:

5556 High capacity Cat7 cable, Class F(A) (1000 MHz), LSZH, 500m, RAL2003 IDLP-CAT7O4-10MO05-RER
5557 High capacity Cat7 cable, Class F(A) (1000 MHz), LSZH, 1000m, RAL2003 IDLP-CAT7O4-10MO10-RER
5558 High capacity Cat7 cable, Class F(A) (1000 MHz), PVC, 500m, RAL7001 IDLP-CAT7O4-10MG05-RER
5559 High capacity Cat7 cable, Class F(A) (1000 MHz), PVC, 1000m, RAL7001 IDLP-CAT7O4-10MG10-RER
5560 High capacity Cat7 cable, Class F(A) (1000 MHz), PE, 500m, RAL9011 IDLP-CAT7O4-10MB05-RER
5561 High capacity Cat7 cable, Class F(A) (1000 MHz), PE, 1000m, RAL9011 IDLP-CAT7O4-10MB10-RER

Technical specifications
Application
indoor/outdoor
Class FA (1000 MHz), PoE/PoE+
IEEE 802.3: 10Base-T, 100Base-T,
1000Base-T, 10GBase-T
IEEE 802.5: 16 MB, ISDN TPDDI, ATM

Standards
according to
ISO/IEC 11801 2nd ed.,
IEC 61156-5, EN 50173-1, EN 50288-9-1

Flame retardancy
EN 60332-1-2 (LSZH-PVC)
Halogen free
EN 60754-1/2 (LSZH)
Smoke density EN 61034-2 (LSZH)

Conductors 4x2x AWG22
Material
Cu
Diameter ᴓ [mm]
0.59

Insulation conductors

Material
Skin-Foam-Skin PE
Diameter ᴓ [mm]
1.4

1st shielding (per conductor pair)

Material
Al/PET foile
Drain wire (material/ᴓ)
Bare copper, tinned / AWG26

2nd shielding
braid
Material
CuSn
Braid coverage [%]
40

Outer sheath

Material
FRNC/LSZH (1), PVC (2), PE(3)
Sheath diameter ᴓ [mm]
7.5
Sheath colour
orange (RAL 2003)(1)
grey (RAL 7001)(2)
black (RAL 9011)(3)
RoHS compliant
yes
Characteristics
UV protected, fire retardant, footage marker
70 ⁰C, EN 50290-2-27 (1)
70 ⁰C, EN 50290-2-22 (2)
80 ⁰C, EN 50290-2-24 (3)

Electrical data

DC conductor resistance [Ω/km]
max. 68
Resitance unbalanced [%]
2
Insulation resistance [mΩ/m]
min. 5000
Mutual capacitance [pF/m]
nom. 42
Capacitance unbalance @ 800 Hz [pF/km]
max. 1600
Impedance @ 100 MHz [Ω]
100 ±5
Coupling attentuation (Type 1) [dB]
min. 85
Velocity rate [%]
78 ~ 80
Propagation delay [ns/100m]
max. 430
Skew @ 100 MHz [ns/100m]
max. 25
Testing voltage [kV]
1
Operation voltage [V]
125

Transmission data at 20 ⁰C @

Attenuation typ. [dB/100m] Attenuation typ. [dB/100m]
1 MHz
1.9
4 MHz
3.5
10 MHz
5.4
100 MHz
17.4
200 MHz
24.9
250 MHz
27.8
500 MHz
40.1
600 MHz
43.8
800 MHz
50.1
1000 MHz
59
1200 MHz
64
1500 MHz
-

Return loss typ. [dB]
Return loss typ. [dB]
1 MHz
26
4 MHz
30
10 MHz
33
100 MHz
33
200 MHz
32
250 MHz
30
500 MHz
28
800 MHz
23
600 MHz
25
1000 MHz
20
1200 MHz
20
1200 MHz
-

Transfer impedance [mΩ/m] @

1 MHz
5
10 MHz
5
30 MHz
10

Near end crosstalk (NEXT) [dB] @

30 MHz - 100 MHz
typ. > 95

Mechanical data

Operating temperature
-20 ⁰C ~ +60 ⁰C
Installation temperature
0 ⁰C ~ +50 ⁰C
Bending radius (installation/as installed) [mm]
8x D / 4x D
Tensile strength [N]
120
Cable weight [kg/km]
60(LSZH), 59(PVC), 54(PE)
Copper content. [kg/km]
30