This category 7 S/FTP data cable is characterized by high performance reserves and outstanding quality, with excellent shielding performance thanks to individually shielded pairs and a tinned copper braid overall shield. Suitable for information transfer systems up to 500MHz, 10Gbps Ethernet Signal transmission in audio, video and data applications. For structured cabling according to ANSI EIA / TIA 568, ISO / IEC 11801 and EN 50173 Class EA.





Available packages and colors:

5550 Advanced Cat7 cable, Class F (500 MHz), LSZH, 500m, RAL4007 IDLH-CAT7O4-05MV05-RER
5551 Advanced Cat7 cable, Class F (500 MHz), LSZH, 1000m, RAL4007 IDLH-CAT7O4-05MV10-RER
5552 Advanced Cat7 cable, Class F (500 MHz), PVC, 500m, RAL7001 IDLH-CAT7O4-05MG05-RER
5553 Advanced Cat7 cable, Class F (500 MHz), PVC, 1000m, RAL7001 IDLH-CAT7O4-05MG10-RER
5554 Advanced Cat7 cable, Class F (500 MHz), PE, 500m, RAL9011 IDLH-CAT7O4-05MB05-RER
5555 Advanced Cat7 cable, Class F (500 MHz), PE, 1000m, RAL9011 IDLH-CAT7O4-05MB10-RER

Technical specifications
Application
indoor/outdoor
Class EA (500 MHz), PoE/PoE+
IEEE 802.3: 10Base-T, 100Base-T,
1000Base-T, 10GBase-T
IEEE 802.5: 16 MB, ISDN TPDDI, ATM

Standards
according to
ISO/IEC 11801 2nd ed., IEC 61156-5,
EN 50173-1, EN 50288-4-1

Flame retardancy
EN 60332-1-2 (LSZH-PVC)
Halogen free
EN 60754-1/2 (LSZH)
Smoke density EN 61034-2 (LSZH)

Conductors 4x2x AWG22
Material
Cu
Diameter ᴓ [mm]
0.57

Insulation conductors

Material
Skin-Foam-Skin PE
Diameter ᴓ [mm]
1.36

1st shielding (per conductor pair)

Material
Al/PET foile
Drain wire (material/ᴓ)
Bare copper, tinned / AWG26

2nd shielding
braid
Material
CuSn
Braid coverage [%]
40

Outer sheath

Material
FRNC/LSZH (1), PVC (2), PE(3)
Sheath diameter ᴓ [mm]
7.4
Sheath colour
violet (RAL 4007)(1)
grey (RAL 7001)(2)
black (RAL 9011)(3)
RoHS compliant
yes
Characteristics
UV protected, fire retardant, footage marker
70 ⁰C, EN 50290-2-27 (1)
70 ⁰C, EN 50290-2-22 (2)
80 ⁰C, EN 50290-2-24 (3)

Electrical data

DC conductor resistance [Ω/km]
max. 75
Resitance unbalanced [%]
2
Insulation resistance [mΩ/m]
min. 5000
Mutual capacitance [pF/m]
nom. 42
Capacitance unbalance @ 800 Hz [pF/km]
max. 1600
Impedance @ 100 MHz [Ω]
100 ±5
Coupling attentuation (Type 1) [dB]
min. 85
Velocity rate [%]
78 ~ 80
Propagation delay [ns/100m]
max. 430
Skew @ 100 MHz [ns/100m]
max. 25
Testing voltage [kV]
1
Operation voltage [V]
125

Transmission data at 20 ⁰C @

Attenuation typ. [dB/100m] Attenuation typ. [dB/100m]
1 MHz
1.8
4 MHz
3.3
10 MHz
5.3
100 MHz
17.5
200 MHz
25.2
250 MHz
28
500 MHz
40.5
600 MHz
44.5
800 MHz
55
1000 MHz
57
1200 MHz
-
1500 MHz
-

Return loss typ. [dB]
Return loss typ. [dB]
1 MHz
26
4 MHz
30
10 MHz
33
100 MHz
33
200 MHz
32
250 MHz
30
500 MHz
27
800 MHz
22
600 MHz
25
1000 MHz
21
1200 MHz
-
1200 MHz
-

Transfer impedance [mΩ/m] @
Grade 1
1 MHz
5
10 MHz
5
30 MHz
10

Near end crosstalk (NEXT) [dB] @

30 MHz - 100 MHz
typ. > 95

Mechanical data

Operating temperature
-20 ⁰C ~ +60 ⁰C
Installation temperature
0 ⁰C ~ +50 ⁰C
Bending radius (installation/as installed) [mm]
8x D / 4x D
Tensile strength [N]
110
Cable weight [kg/km]
55(LSZH), 54(PVC), 48(PE)
Copper content. [kg/km]
28


© 2017 FTA Communication Technologies S.à r.l.   Legal terms of usePrivacy policy Site by Medya-T